<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-04 11-22-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 56 dBuV SANDELS
Pilot RDS Phase Difference
6.7 kHz 6.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 51 kHz 17069 5,4485
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-2,8 dBr 1,58 dBr 3,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 51 kHz MIN: 12 kHz % above 76 kHz: 5,4485 Acquired: 2024/08/04 11.21.17 Total samples: 17069 Equivalent time: 0:14:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 3,4 dBr MIN: -2,8 dBr AVE: 1,58 dBr % above 12,2 dBr: 0,0 Last value: 3,1 dBr (2024/08/04 11.21.17) 11.08 11.10 11.12 11.14 11.16 11.18 11.20 -2 0 2 4 Pm [dBr]